Usage amount per sample:
| Chemical | Concentration | Amount | Location |
|---|---|---|---|
| β-mercaptoethanol ( β-ME ) | − | 3.5 μL | Toxic (b) |
| Buffer RLT mixture α | − | 350 μL | RNA bench |
| Buffer RW1 β | − | 700 μL | RNA bench |
| Buffer RPE mixture γ | − | 500 μL | RNA bench |
| Buffer RDD | − | 70 μL | 4°C (b) |
| DNAse I incubation mix δ | − | 80 μL | fresh-prepared |
| Ethanol (EtOH) (for RNA use) | ≥ 96% | — | Ⅴ |
| Ethanol (EtOH) | 80% | 500 μL | fresh-prepared |
| Ethanol (EtOH) | 70% | 350 μL | fresh-prepared |
| RNase-free water | − | 14 μL | RNA bench |
- DNase Ⅰ stock solution: Located at 4°C (b). Dissolve the lyophilized DNase Ⅰ in 550 μL RNase-free water. To avoid loss of DNase Ⅰ, do not open the vial. Inject RNase-free water into the vial using an RNase-free needle and syringe. Mix gently by inverting the vial. Do not vortex. Store the stock solution as single use aliquots at −20°C (9 months) or 4°C (1 month). Do not refreeze after thawing.
- Buffer RDD: Located at 4°C (b). It provides efficient on-column digestion of DNA and also ensures that the RNA remains bound to the column.
- Put the tissue into an eppendorf, slightly centrifuge to spin down the tissue to the bottom of the eppendorf. If the tissue is not used immediately, store the sample at -80°C.
Close the eppendorf lid tightly, and then immediately put the eppendorf into liquid nitrogen ( it will float up by itself, no worry ).
The drill of the TissueLyser instrument should be pre-cold, by inserting it into the liquid nitrogen.
Take out the eppendorf and powderize the tissue with the TissueLyser instrument ( this step is extremely important to yield high quantity and quality of RNA, and this step also should be finished as quick as possible ).
Add 350 μL Buffer RLT mixture into the eppendorf and immediately vortex to homogenize the buffer and the powderized tissue ( 10-15 secs )
Now we get the raw lysate. Place the eppendorf on ice to inhibit enzymatic activity of the lysate.
Centrifuge the raw lysate ( 3 mins, 15000 rpm ).
Carefully take the supernatant to a new eppendorf, and then place on ice.
Add 350 μL 70% EtOH into the sample, mix well with pipetting. DO NOT centrifuge. Proceed to the next step immediately.
Transfer the sample ( including any precipitate that may have formed ) to an RNeasy MinElute® spin column in a 2 mL collection tube. Close the lid and centrifuge ( 4°C, 1 min, ≥ 15000 rpm ). Discard the flow-through and reuse the collection tube for the next step.
Add 350 μL Buffer RW1 to the RNeasy MinElute® spin column. Close the lid and centrifuge ( 4°C, 1 min, ≥ 15000 rpm ). Discard the flow-through and reuse the collection tube for the next step.
- Be sure to add the DNase I incubation mix directly to the RNeasy MinElute spin column membrane. DNase digestion will be incomplete if part of the mix sticks to the walls or the O-ring of the spin column
- The DNase I incubation mix (80 μL) should be fresh-prepared. Add 10 µL DNase I stock solution to 70 µL Buffer RDD, mix by inverting the tube, and put on ice. Please refer to the first page for details.
Add 350 μL Buffer RW1 to the RNeasy MinElute® spin column. Close the lid and centrifuge ( 4°C, 1 min, ≥ 15000 rpm ). Discard the flow-through and collection tube.
Place the RNeasy MinElute® spin column in a new 2 mL collection tube (supplied). Add 500 μL Buffer RPE to the spin column. Close the lid and centrifuge ( 4°C, 1 min, ≥ 15000 rpm ). Discard the flow-through and reuse the collection tube.
Add 500 μL 80% EtOH to the spin column. Close the lid and centrifuge 2 times ( 2 × 2 mins, ≥ 15000 rpm ). Discard the flow-through and collection tube.
- After centrifugation, carefully remove the RNeasy MinElute spin column from the collection tube so that the column does not contact the flow-through. Otherwise, carryover of ethanol will occur.
- To avoid damage to their lids, place the spin columns into the centrifuge with at least one empty position between columns. Orient the lids so that they point in a direction opposite to the rotation of the rotor (e.g., if the rotor rotates clockwise, orient the lids counterclockwise)
Place the RNeasy MinElute® spin column in a new 1.5 mL RNase-free low-binding collection tube (supplied).
Add 14 µL RNase-free water directly to the center of the spin column membrane. Close the lid gently.
Centrifuge at full speed ( 4°C, 1 ~ 15 mins, ≥ 15000 rpm ) to elute the RNA.
Store the RNA eluate at −20°C ( few weeks ) or −80°C ( > 1 year ).
| NanoDrop™ | Qubit™ | |
|---|---|---|
| Concentration ( > 100 ng / uL ) | ✓ | ✓ |
| Concentration ( < 10 ng / uL ) | ✓ | |
| Require high precision | ✓ | |
Buffer RLT (store at 15 - 25°C)
Buffer RPE (working solution) (store at 15 - 25°C)
Buffer RDD (store at 15 - 25°C)
Buffer RW1 (store at 15 - 25°C)
DNase Set (RNase-Free) (store at 2 - 8°C)
RNeasy MinElute® spin columns (store at 2 - 8°C)
2 mL collection tube
1.5 mL collection tube
For best results, ensure that all materials and reagents are at room temperature.
The working solution is a mixture of Component A (dye) and Component B (HS buffer), with a ratio of 1 : 199. For example, to make 10 tubes (8 samples + 2 standards), add 10 μL dye into 1990 μL HS buffer.
Standard assay tubes User sample assay tubes Volume of working solution 190 μL 180 – 199 μL Volume of standard 10 μL — Volume of user sample — 1 – 20 μL Total volume in each assay tube 200 μL 200 μL
Home screen, touch RNA, then select RNA High Sensitivity as the assay type. Touch Read standards to proceed.Read standard. When the reading is comnplete, remove Standard # 1.Read standard. When the reading is comnplete, remove Standard # 2.Run samples.Sample volume and Unit.Unit dropdown menu, select the units for the output sample concentration.Read tube. When the reading is complete ( ~ 3 seconds ), remove the sample tube.| Component | Material name | Q32852 * | Concentration |
|---|---|---|---|
| A ☨ | Qubit™ RNA HS Reagent | 250 μL | 200X in DMSO |
| B § | Qubit™ RNA HS Buffer | 50 mL | ‐ |
| C ※ | Qubit™ RNA HS Standard # 1 | 1 mL | 0 ng/μL in TE buffer |
| D ※ | Qubit™ RNA HS Standard # 2 | 4 × 250 μL | 10 ng/μL in TE buffer |
* Q32852: Catalogue number. When stored as directed, kits are stable for 6 months.
☨ Component A: Stored at 2 ~ 8°C ( short-term storage ) or ≤ -20°C ( long-term storage ), desiccated, protect from light. Located at -80°C, upper door, 2nd layer, 2nd column, 3rd drawer, 10 µL pale blue aliquots in PCR tubes.
§ Component B: Stored at ≤ 30 °C. Located at VI.
※ Component C & D: Stored at 2 ~ 8°C ( short-term storage ) or ≤ -20°C ( long-term storage ). Located at -80°C, upper door, 2nd layer, 2nd column, 3rd drawer.